DOL 51は、高湿度用途でのアンモニア (NH3) 濃度の連続測定用に特別に設計されたアンモニアセンサーで、受賞歴のある DOL 53 の機能を拡張したものです。
DOL 51 is an ammonia sensor specifically designed for continuous measurement of ammonia (NH3) concentration in applications with high air humidity, expanding the features of the award-winning DOL 53.
Tecnical Information 技術情報 | |
---|---|
Output voltage range 出力電圧範囲 | 0-10 V DC 0-10 V DC |
Output power range 出力電力範囲 | 4-20 mA 4-20 mA |
Load for voltage output 電圧出力負荷 | > 500 - < 10M Ω > 500 - < 10M Ω |
Recommended load, voltage output 推奨負荷、電圧出力 | > 100 kΩ > 100 kΩ |
Load for current output 電流出力の負荷 | > 100 - < 470Ω > 100 - < 470Ω |
Measuring range 測定範囲 | 0-50 ppm NH3 0-50 ppm NH3 |
Voltage resolution 電圧分解能 | 0.2 V/ppm NH3 0.2 V/ppm NH3 |
Resolution 分解能 | 0.32 mA/ppm 0.32 mA/ppm |
Signal transmission resolution 信号伝送分解能 | 0.5 ppm NH3 0.5 ppm NH3 |
Accuracy 精度 | 1.5 ppm or +10% of the measured value 1.5 ppm、または測定値の +10% |
Long term drift 長期ドリフト | < +10% of the measured value 測定値の +10 % 未満 |
DOL 51は、高湿度用途でのアンモニア (NH3) 濃度の連続測定用に特別に設計されたアンモニアセンサーで、受賞歴のある DOL 53 の機能を拡張したものです。
DOL 51 の革新的な設計により、センサーは畜舎内など、湿度が 95 % ~ 100 % と非常に高い過酷な条件下でも動作できます。空気は、結露を防止する加熱ダクトを通って測定口に送られます。dol-sensors のセンサーすべてと同様に、DOL 51 は十分にテストされているため、校正を必要とせずに長寿命です。
DOL 51は、最大 50 ppm の濃度で正確なアンモニア測定が可能で、他のガスとの交差感度はごくわずかです。DOL 51 は、チューブやポンプを必要とせずにエアストリームに直接取り付けられます。
DOL 51 は、空気清浄機のクリーンガス側のフィルターを通過した後に残留するアンモニア濃度を測定します。このデータは、排気の清浄度を記録するために不可欠です。
DOL 51 のデータに空気清浄機の吸気側にある DOL 53 のデータと組み合わせることで、添加剤のコストを最小限に抑えながら、空気清浄機が可能な限り効率的に動作することを保証できます。
DOL 51 is an ammonia sensor specifically designed for continuous measurement of ammonia (NH3) concentration in applications with high air humidity, expanding the features of the award-winning DOL 53.
The innovative design of DOL 51 allows the sensor to operate under harsh conditions with extremely high humidity 95 % – 100 % , eg. in livestock houses. The air is funneled to the measuring inlet through a heated duct that prevents condensation. As all sensors from dol-sensors, DOL 51 is well tested and therefore has a long service life without the need for calibration.
The DOL 51 provides accurate ammonia measurements in concentrations up to 50ppm and has negligible cross sensitivity to other gasses. DOL 51 is mounted directly in the airstream without any need for tubes or pumps.
DOL 51 measure the remaining ammonia concentration after passage of the filters on the clean gas side of the air cleaners. This data is vital to document the cleanness of the exhaust air.
Combined with data from DOL 53 on the inlet side of the air cleaner, data from DOL 51 can be used to ensure that air cleaners run as efficiently as possible at the lowest possible cost of additives.